gefran ADL300 EPC v2 User Manual page 44

Application: elevator position control sieidrive
Table of Contents

Advertisement

4 Fast Stop
5 Lift Stop
Menu
Par
Description
5.9.3
11562
Lim Activity
Setting of the behaviour of the drive if the "Limit" alarm is present. This alarm indicates that the rephaser
limits have been exceeded (upper/lower limit).
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast Stop
5 Lift Stop
Menu
Par
Description
5.9.4
11564
Door Activity
Setting of the behaviour of the drive if the Door Feedback alarm is present. This alarm indicates that
feedback has not been received to confirm door opening.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast Stop
5 Lift Stop
Menu
Description
Par
5.9.5
11566
Contactor Activity
Setting of the behaviour of the drive if the Contactor Feedback alarm is present. This alarm indicates
that feedback has not been received to confirm contactor closing.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast Stop
5 Lift Stop
Menu
Par
Description
5.9.6
11568
Brake Activity
Setting of the behaviour of the drive if the Brake Feedback alarm is present. This alarm indicates that
feedback has not been received to confirm brake opening/closing.
0 Ignore
1 Warning
2 Disable
3 Stop
4 Fast Stop
5 Lift Stop
Menu
Description
Par
5.9.7
11572
Brake run hold off
Setting of the behaviour of the drive upon detecting the possible Brake Feedback alarm.
0 Ignore
1 Warning
ADL300-EPCv2- User Guide
UM
Type
INT16
UM
Type
INT16
UM
Type
INT16
UM
Type
INT16
UM
Type
INT16
____________________ _
FB BIT
Def
Min
1
0
FB BIT
Def
Min
1
0
FB BIT
Def
Min
1
0
FB BIT
Def
Min
1
0
FB BIT
Def
Min
1
0
Max
Acc
Mod
5
RW
FVS
Max
Acc
Mod
5
RW
FVS
Max
Acc
Mod
5
RW
FVS
Max
Acc
Mod
5
RW
FVS
Max
Acc
Mod
1
RW
FVS
Page 44 of 64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sieidrive adl300 epc

Table of Contents