9.3.2 Configurable Output Signals

All the configurable output signals of this relay are listed in following table.
No.
Output Signal
1
FD.Pkp
2
50/51P1.St
3
50/51P1.Op
4
50/51P2.St
5
50/51P2.Op
6
50/51P3.St
7
50/51P3.Op
8
50/51P4.St
9
50/51P4.Op
10
50/51P5.St
11
50/51P5.Op
12
50/51P6.St
13
50/51P6.Op
14
50/51Q1.St
15
50/51Q1.Op
16
50/51Q2.St
17
50/51Q2.Op
18
50/51G1.St
19
50/51G1.Op
20
50/51G2.St
21
50/51G2.Op
22
50/51G3.St
PCS-9611 Feeder Relay
The interlock check signal of the No.3 manual tripping element
The interlock check signal of the No.3 manual closing element
The interlock check signal of the No.4 manual tripping element
The interlock check signal of the No.4 manual closing element
The interlock check signal of the No.5 manual tripping element
The interlock check signal of the No.5 manual closing element
The binary signal for switching to the No.1 setting group
The binary signal for switching to the No.2 setting group
The binary signal for switching to the No.3 setting group
The binary signal for switching to the No.4 setting group
The binary input for denoting the local VT is in service, default is "1"
The binary input for inputting the external voltage control signal
The input of the No.1 DC analog output
The input of the No.2 DC analog output
The input of the No.3 DC analog output
The input of the No.4 DC analog output
The fault detector operates.
The stage 1 overcurrent protection picks up.
The stage 1 overcurrent protection operates.
The stage 2 overcurrent protection picks up.
The stage 2 overcurrent protection operates.
The stage 3 overcurrent protection picks up.
The stage 3 overcurrent protection operates.
The stage 4 overcurrent protection picks up.
The stage 4 overcurrent protection operates.
The stage 5 overcurrent protection picks up.
The stage 5 overcurrent protection operates.
The stage 6 overcurrent protection picks up.
The stage 6 overcurrent protection operates.
The stage 1 negative sequence overcurrent protection picks up.
The stage 1 negative sequence overcurrent protection operates.
The stage 2 negative sequence overcurrent protection picks up.
The stage 2 negative sequence overcurrent protection operates.
The No.1 stage 1 zero sequence overcurrent protection picks up.
The No.1 stage 1 zero sequence overcurrent protection operates.
The No.1 stage 2 zero sequence overcurrent protection picks up.
The No.1 stage 2 zero sequence overcurrent protection operates.
The No.1 stage 3 zero sequence overcurrent protection picks up.
Date: 2014-04-08
9 Configurable Function