7 Settings
1
2
3
If this setting is set as "1", if this device does not receive time synchronization message or
receives error time synchronization message, it will alarm; and if this setting is set as "0" or
"2", if this device does not receive the time synchronization signal, it will alarm and switch to
message time synchronization mode automatically.
11. The setting [IP_Server_SNTP] is used to set the IP address of the SNTP server, if this relay
adopts the SNTP time synchronization. If the SNTP time synchronization is not adopted, it is
recommended to set as "000.000.000.000".
12. If the IEC61850 protocol is adopted in substations, the time tags of communication messages
are required according to UTC (Universal Time Coordinated) time.
The setting [OffsetHour_UTC] is used to set the hour offset of the current time zone to the
GMT (Greenwich Mean Time) zone; for example, if a relay is applied in China, the time zone
of China is east 8
used to set the minute offset of the current time zone to the GMT zone.
Time zone
Setting
Time zone
Setting
Time zone
East/West 12
Setting
Time zone
Setting
13. The setting [En_DualNet_GOOSE] is used to enable or disable the dual-network GOOSE
function if the GOOSE function is supported in this relay. If it is set as "1", the dual-network
GOOSE function is adopted; otherwise, the single-network GOOSE function is adopted.
14. The setting [Format_Setting_DNP] is used to select the data type of the settings of the DNP
3.0 communication protocol. "0": NULL; "1" Analog Output; "2": Analog Input.

7.7 Copy Settings

It (the submenu "Copy Settings") is used to copy the active settings to another group, see
Section 8.2.6.3 for more details.
7-34
Message time synchronization mode: SNTP protocol (unicast or broadcast),
other SAS time synchronization message (such as IEC60870-5-103) etc.
Extension module time synchronization mode: PPS signal (Optical interface),
IRIG-B signal (Optical interface)
No external time synchronization source
th
time zone, so this setting is set as "8". The setting [OffsetMinute_UTC] is
GMT zone
East 1
0
1
th
East 6
East 7
6
7
th
West 1
-12/12
-1
th
West 6
West 7
-6
-7
Date: 2014-04-08
st
nd
East 2
East 3
2
3
th
th
East 8
East 9
8
9
st
nd
West 2
West 3
-2
-3
th
th
West 8
West 9
-8
-9
rd
th
East 4
East 5
4
5
th
th
East 10
East 11
10
11
rd
th
West 4
West 5
-4
-5
th
th
West 10
West 11
-10
-11
PCS-9611 Feeder Relay
th
th
th
th

Advertisement

Table of Contents
loading

Table of Contents