CYLINDER HEAD TEMPERATURE GAUGE.
The cylinder head temperature gauge is in the instrument cluster, located on the instrument panel. This
instrument measures the cylinder head temperature using a sender located in a cylinder head. The head
location is determined by the engine manufacturer. It is an electrical instrument and is wired thru the
instruments circuit breaker.
CHART 7706. CYLINDER HEAD TEMPERATURE GAUGE
Trouble
Cause
Remedy
Instrument shows no
indication.
Power supply wire
broken.
Repair wire.
Defective instrument.
Replace instrument.
Master switch off.
Instrument goes all
the way to upper stop.
Wire broken between
sender and gauge.
Repair wire.
Defective sender.
Replace sender.
-END-