Piper SARATOGA PA-32-301 Maintenance Manual page 391

Hide thumbs Also See for SARATOGA PA-32-301:
Table of Contents

Advertisement

1. OXYGEN BOTTLES
2. MOUNTING BRACKET
3. FACE MASK
Figure 35-8. Oxygen Installation (Portable)
TESTING FOR LEAKS.
Apply detector fluid type CD-1 solution or its equivalent. The solution should be shaken to obtain suds or
foam. The suds or foam should be applied sparingly to thejoints of a closed system. Look for traces of bubbles.
No visible leakage should be found. Repair or replace any defective parts and retest system.
With the system pressurized to service pressure. further tests can be made. The rate of any leak should not
exceed one percent of the total supply per 24 hour period. All traces of the detector fluid should be wiped off at
the conclusion of the examination.
MAINTENANCE.
PIPER AIRCRAFT
PA-32-301/301T
MAINTENANCE MANUAL
2
1. Check the cylinder to be sure it is securely mounted.
2. Check the cylinder for the ICC identification number and for the date of the last FAA inspection and
test.
3. If cylinder is completely empty it must be completely disassembled and inspected in an FAA or
manufacturer approved facility before recharging.
4. Refer to FAA Manual AC 43.13-1A for more details.
35-10-21
Page 35-19
2F2
Added: May 21, 1980