Piper SARATOGA PA-32-301 Maintenance Manual page 505

Hide thumbs Also See for SARATOGA PA-32-301:
Table of Contents

Advertisement

PIPER AIRCRAFT
PA-32-301/301T
MAINTENANCE MANUAL
2. The mixture may be adjusted as follows:
A. At the fuel injector. disconnect the clevis end of the mixture control cable from the control arm.
Loosen the jam nut that secures the clevis end.
B. Adjust the linkage by rotating the clevis end on the cable to obtain 0.010 to 0.030 of an inch
spring back on the instrument panel stop when in full rich position.
C.
Reconnect the clevis end to the control arm and safety.
3. Check security of cable casing attachments.
4.
Pull the throttle and mixture levers in the cockpit full aft to ascertain that the idle screw contacts its
stop and the mixture control arm contacts its lean position. A mixture control lock is incorporated in the
quadrant cover which prevents the mixture control from being moved to the idle cutoff position inadvertently.
The lock must be depressed before the control can be moved completely aft. Ascertain that the lock operates
freely without any tendency to bind or hang up.
-END-
73-20-01
Page 73-07
Issued: January 2, 1980
2J22

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Saratoga pa-32-301t

Table of Contents