Specifications
TABLE 2-6
NAME
SPARC Enterprise M8000 server + Power Cabinet
SPARC Enterprise M9000 server
(base cabinet) + Power Cabinet
SPARC Enterprise 9000 server
(base cabinet + expansion cabinet) + Power Cabinet
* The values for maximum power consumption and apparent power vary by the type of CPU mounted. To plan the installation of a serv-
er equipped with different types of CPU, use the CPU of larger power consumption as a basis. For the types of CPU, see Section 3.3.6,
"CPU Types and Server Maximum Power Consumption" of the Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide..
Specifications
TABLE 2-7
NAME
SPARC Enterprise M8000 server + Power Cabinet
SPARC Enterprise M9000 server
(base cabinet) + Power Cabinet
SPARC Enterprise 9000 server
(base cabinet + expansion cabinet) + Power Cabinet
* The values for maximum power consumption and apparent power vary by the type of CPU mounted. To plan the installation of a serv-
er equipped with different types of CPU, use the CPU of larger power consumption as a basis. For the types of CPU, see Section 3.3.6,
"CPU Types and Server Maximum Power Consumption" of the Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide..
CPU Types and Server Maximum Power
Consumption
The CPU Types and Power Specifications information found in Section 3.3.6 of the
Sun SPARC Enterprise M8000/M9000 Servers Site Planning Guide will be updated with
the information that appears below, including the following tables.
This section describes the CPU types and the maximum power consumption of the
server. There are four types of CPU. The power specifications of the SPARC
Enterprise M8000/M9000 servers vary depending on the CPU type and the system
configurations.
*
(Three-Phase Delta Power Requirements)
*
(Three-Phase Star Power Requirements)
Power consumption [kW]
3.88-10.49
6.20-19.87
11.92-39.72
Power consumption [kW]
3.88-10.49
6.20-19.87
11.92-39.72
Chapter 2
Apparent power [kVA]
4.11-11.12
6.58-21.07
12.64-42.13
Apparent power [kVA]
4.11-11.12
6.58-21.07
12.64-42.13
Information About Hardware