General Functionality Issues And Limitations - Sun Microsystems SPARC Enterprise M8000 Product Notes

Xcp version 1091
Hide thumbs Also See for SPARC Enterprise M8000:
Table of Contents

Advertisement

General Functionality Issues and Limitations

Caution – For dynamic reconfiguration (DR) and hot-plug issues, see
Issues and Workarounds" on page
You cannot use the following user account names, as they are reserved for system
use: adm, admin, apache, bin, daemon, default, ldap, nobody, ntp,
operator, proxyuser, root, rpc, rpcuser, and sshd.
Do not use the Service Processor (SP) as the Network Time Protocol (NTP) server.
Using an independent NTP server provides optimal reliability in maintaining
consistent time on the SP and the domains. For more information about NTP, see
the Sun BluePrints
Clocks:
When you use the external power control interface of the external power
controller, the following notification signals are not supported:
When you import XCP or update the firmware using the XSCF you might see
Web session ID errors displayed on the web browser. When you specify the
timeout period as over 30 minutes in the Autologout setting Internal Server
Errors might be displayed. To reconnect to the XSCF Web, close the current
browser and open the new browser.
For this XCP release, the XSCF browser user interface (XSCF Web) does not
support the External I/O Expansion Unit Manager feature.
Disable pop-up blocking and remove any plug-ins such as the search tool
installed with the browser when you use the XSCF Web.
XSCF-LAN is compliant with auto-negotiation. Set the network device which
connects with XSCF-LAN to the auto-negotiation mode. Otherwise when you
connect the XSCF-LAN and the network device (fixed to the full-duplex mode,
according to the IEEE 802.3 rule) the XSCF-LAN communicates in half-duplex
mode and network communication speed might slow down or communication
errors may occur.
Due to DR and ZFS file system interoperability issues, M8000/M9000 servers are
shipped pre-installed using the UFS file system. For more information, refer to the
description and workaround for CR 6522017 in
For information about I/O options and storage, such as the number of cards
supported in a domain, see the Sun Cross Platform IO Support page:
http://wikis.sun.com/display/PlatformIoSupport/Home/
Do not use the CD-RW/DVD-RW drive unit and the TAPE drive unit at the same
time.
12
Sun SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1091 • May 2010
document, Using NTP to Control and Synchronize System
http://www.sun.com/blueprints/0701/NTP.pdf
The OS panic or the server hardware error signal (*CPUN/RTNU)
The server hardware error signal (power fail, temperature error, and fan error)
39.
TABLE 3-2
"Solaris OS
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sparc enterprise m9000

Table of Contents