Not; Nor - Reer MOSAIC M1 Installation And Use Manual

Modular safety integrated controller
Hide thumbs Also See for MOSAIC M1:
Table of Contents

Advertisement

NOT

Logical NOT inverts the logical status of the
input.
In
Out
0
1
1
0
OR
Logical OR returns an output of 1 (TRUE) if at
least one of the inputs is 1 (TRUE).
In
In
In
1
2
0
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
1
1
1
Parameters
Number of inputs: this is used to set between 2 and 8 inputs.

NOR

Logical NOR returns an output of 0 (FALSE) if at
least one of the inputs is 1 (TRUE).
In
In
In
1
2
0
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
1
1
1
Parameters
Number of inputs: this is used to set between 2 and 8 inputs.
172
Out
x
0
1
1
1
1
1
1
1
Out
x
1
0
0
0
0
0
0
0
MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC