Clocking - Reer MOSAIC M1 Installation And Use Manual

Modular safety integrated controller
Hide thumbs Also See for MOSAIC M1:
Table of Contents

Advertisement

MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC

CLOCKING

The CLOCKING operator generates a square wave output
which period is set by the user. The output is enabled if
inputs to control output Duty Cycle.
Parameters
Time: The period can be set to between 100 ms and
1098,3 s.
Scale: The user can choose two different scales for the
time T to be set.
100 ms...60 s, step 10 ms
60,1 s...1098,3 s, step 100 ms
Duty cycle selection: Up to 7 inputs can be selected for 7 different output signal duty
cycles. Depending on the active input, the OUT clock signal has its corresponding duty
cycle. EN input must always be to 1 (TRUE).
Refer to the table below for all possible values of Duty cycle selectable by the user.
EN
10%
0
0
1
0
1
1
1
0
1
0
0
1
1
0
1
0
0
1
1
1
The circuit upstream clocking operator must ensure the presence of only one input
signal in addition to enable EN (excluded the pair 10% 80%).
The presence on EN input of high level (TRUE), generates an output signal with a duty
cycle = 50%.
8540780 • 10/07/2020 • Rev.38
Clocking has up to 7
DUTY CYCLE CHOICE
20%
30%
40%
0
0
0
0
0
0
1
0
0
1
0
0
0
0
0
0
0
0
0
0
60%
70%
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
1
0
0
0
0
0
0
80%
OUT
0
0
0
50%
0
10%
0
20%
0
30%
0
40%
0
60%
0
70%
1
80%
1
90%
203

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mosaic m1s

Table of Contents