Mi12T8 (Figure 39) - Reer MOSAIC M1 Installation And Use Manual

Modular safety integrated controller
Hide thumbs Also See for MOSAIC M1:
Table of Contents

Advertisement

MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
MI12T8
(Figure 39)
MEANING
Internal fault
Compatibility error
Error in communication with
master
Error on other
slave or M1
Same type of slave with
same address detected
Node detection circuit error
Figure
- MI12T8
39
8540780 • 10/07/2020 • Rev.38
RUN
IN FAIL
EXT FAIL
GREEN
RED
RED
OFF
2 or 3 flashes
OFF
5
OFF
OFF
flashes
5
OFF
OFF
flashes
OFF
ON
OFF
5
5
OFF
flashes
flashes
3
OFF
OFF
flashes
Table 69 - Troubleshooting MI12T8
LED
SEL0/1
IN1÷12
ORANGE
YELLOW
OFF
5
flashes
Shows the physical
OFF
address of the unit
OFF
OFF
3
OFF
flashes
REMEDY
Return the unit to ReeR to be repaired
• Firmware version not compatible with M1,
return to ReeR for FW upgrade.
• Restart the system
• If the problem persists, return the unit to
ReeR to be repaired
• Restart the system
• Check which unit is in FAIL mode
NODE SEL
• Change the unit's address (see
• Return the unit to ReeR to be repaired
)
77