MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
Parameters
External K delay: allows the operator to set the time window within which the external
feedback signal (Fbk_K) is to be monitored (according to output conditions).
Enable Clear: if checked enables input Clear.
With this input at 1 it is possible to clear the error when the fault has been repaired. Using
this input it is no longer necessary to reset M1S or turn off the system.
INTERPAGE IN/OUT
If the scheme is very complicated and requires a connection between two elements very far, use
the "Interpage" component.
INTERPAGE OUT
(scheme
side SX)
The element "Interpage out" must have a name which, invoked by the corresponding
"Interpage in", allows the desired link.
8540780 • 10/07/2020 • Rev.38
Figure 88 – OSSD EDM operator scheme example
INTERPAGE IN
(scheme
side DX)
223