MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
Frequency: It shows the frequencies values calculated starting
from the speed thresholds fM and fm (fm is the fM threshold
frequency decreased by the hysteresis set). If the displayed
value is GREEN, the calculation of frequency gave a positive
result.
If the displayed value is RED, it is necessary to change the
parameters given in the following formulas.
1. rotational axis, rotational sensor. The frequency obtained is:
2. Linear axis, rotational sensor. The frequency obtained is:
3. Linear axis, linear sensor. The frequency obtained is:
4. Hysteresis. To be changed only if: fM=green; fm=red
8540780 • 10/07/2020 • Rev.38
Proximity choice:
KEY:
f = frequency
Rpm = rotational speed
Resolution = measurement
Speed = linear speed
Pitch = sensor pitch
137