Intfbk_In / Intfbk_Out (M1S Only, Max Number = 8); Terminator - Reer MOSAIC M1 Installation And Use Manual

Modular safety integrated controller
Hide thumbs Also See for MOSAIC M1:
Table of Contents

Advertisement

INTFBK_IN / INTFBK_OUT (M1S only, max number = 8)

This operator can be used to create logical loops or to connect the output of a function
block to the input of another function block. IntFbk consist of IntFbk_In and IntFbk_Out;
after one M1S logical cycle delay, every IntFbk_In assumes the same logical value of the
corresponding IntFbk_Out.
INTFBK_IN
(scheme
side SX)
The element "IntFbk_Out" must have a number which, invoked by the corresponding
"IntFbk_In", allows the desired link.
Figure 89 – INTFBK_IN / INTFBK_OUT operator scheme example
If not carefully designed feedback loops could trigger dangerous system oscillations and as a
consequence makes the system instable. An instable system may have severe consequence to
the user like severe injuries or death.

TERMINATOR

This operator can be used as a terminator for
inputs not used in the scheme.
The input connected to the TERMINATOR operator
appears in the input map and its status is
transferred to the BUS.
224
MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC
INTFBK_OUT
8540780 • 10/07/2020 • Rev.38
(scheme
side DX)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mosaic m1s

Table of Contents