General; Catalog/Style Numbering - Eaton H-Max Series Installation Manual

Adjustable frequency drive
Hide thumbs Also See for H-Max Series:
Table of Contents

Advertisement

General

General
This document provides supplement information to the H-Max installation Manual MN04008005E specific to the H-Max
IntelliPass and IntelliDisconnect products. These products are offered with input/output voltages of 208, 230 & 480 VAC with
HP ranges from 1 to 75hp. Both UL Type 1,12 and Type 3R enclosures are available along with several factory wired power
and plug in options.

Catalog/Style Numbering

Eaton HMAX IntelliPass and IntelliDisconnect Catalog Number Matrix
Product:
HMX = HVAC Drive (VT)
Enclosure/Style:
3 = IntelliPass NEMA Type 1
4 = IntelliPass NEMA Type 12
5 = IntelliPass NEMA Type 3R
A = IntelliDisconnect NEMA Type 1
B = IntelliDisconnect NEMA Type 12
C = IntelliDisconnect NEMA Type 3R
NEC 208 Volts:
NEC 230 Volts:
4D6 = 4.6 Amp = 1.0 HP
4D2 = 4.2 Amp = 1.0 HP
7D5 = 7.5 Amp = 2 HP
6D8 = 6.8 Amp = 2 HP
011 = 11 Amp = 3 HP
9D6 = 9.6 Amp = 3 HP
017 = 17 Amp = 5 HP
016 = 16 Amp = 5 HP
025 = 24 Amp = 7.5 HP
022 = 22 Amp = 7.5 HP
031 = 31 Amp = 10 HP
028 = 28 Amp = 10 HP
047 = 47 Amp = 15 HP
042 = 42 Amp = 15 HP
060 = 60 Amp = 20 HP
054 = 54 Amp = 20 HP
075 = 75 Amp = 25 HP
068 = 68 Amp = 25 HP
088 = 88 Amp = 30 HP
080 = 80 Amp = 30 HP
104 = 104 Amp = 40 HP
Notes:
All Boards are Varnished
Battery Included in all drives for real time clock
EMC = EMC C2 Standard
Graphic keypad on all drives
Bypass & HOA Keypad
4
H-Max Series Drives IntelliPass®/IntelliDisconnect® IL04008003E April 2013
HMX 011
3
Voltage:
Braking:
1 = 208V
2 = 230V
N = No Brake Chopper
4 = 480V
(Low Overload)
5 = 575V
B = Internal Brake
Chopper Low
NEC 480 Volts:
2D1 = 2.1 Amp = 1 HP
3D4 = 3.4 Amp = 2 HP
5D6 = 5.6 Amp = 3 HP
7D6 = 7.6 Amp = 5 HP
011 = 11 Amp = 7.5 HP
014 = 14 Amp = 10 HP
021 = 21 Amp = 15 HP
027 = 27 Amp = 20HP
034 = 34 Amp = 25 HP
040 = 40 Amp = 30 HP
052 = 52 Amp = 40 HP
065 = 65 Amp = 50 HP
077 = 77 Amp = 60 HP
096 = 96 Amp = 75 HP
4
N
A
P3
Software Options:
A - Standard
Intellipass/Options:
00 =None
P3 = Drive Isolation Fuses
(for FS 4-7 not available with M1, P6 or PE options)
P6 = Drive Isolation Contactor includes drive test switch
(For FS 4-7 not available with M1, P3 or PE options)
L4 = Pilot Lights (not available with M1)
M1 = Manual Bypass - includes pilot lights and Isolation contactor (not
available with any other wired option)
IS = Isolation Switch not available with M1, P6 or PE options
SA = Space Heater w/Xformer (Type 3R only)
K9 = Aux Contacts
Intellidisconnect Options:
00 = None
P3 = Drive Isolation Fuses
PE = Drive Output contactor
L3 = HMAX Pilot Lights
SA = Space Heater w/Xformer (Type 3R only)
K9 = Aux Contacts
Extended I/O Options in Slot D & E:
B1 = 6 DI or DO, 1 ext +24V DC/EXT +24V DC Programmable
B2 = 1 RO (NC/NO), 1 RO (NO), 1 Thermistor
B4 = 1 AI (mA isolated), 2 AO (mA isolated)
B5 = Card-3 Relay Dry Contact
B9 = 1 RO (NO), 5 DI 42 – 240V AC Input
BF = Expander IO - 1*AO, 1*DO, 1*RO
I/O Options in Slot B
F2 = 2 relay and 1 Thermistor- not available with L3/L4 Pilot light
option replaces standard Relay1 pcb in Slot B and Fault Relay function
Optional Communications in Slot D & E:
C4 = OPTC4: Lonworks
On Board Base RS485 Communications:
BACnet MS/TP = MS/TP = Master Slave / Token Protocol (Universal BACnet)
RS 485 ModbusRTU RS485, ASCII or RTU, remote terminal unit 32 Nodes
On Board Ethernet Based Communications:
BACnet/IP Ethernet Industrial Protocol
M = Modbus/TCP Transmission Control Protocol (Ethernet Based) Note
All Boards are Varnished