3.5 FACTORY WIRING SCHEMATIC

LOCAL/REMOTE SWITCH OPTION
(SUFFIX LR)
LOC
(13)
RED
TERMINAL BLOCK 1
ON COVER
10 POS
WHT
BLK
WHT
BLK
FAULT
RUN
A
G
RESET
START
YEL
BLU
(
)
(
)
RED
RED
FIELD LINE WIRING

3.6 COMMUNICATION AND I/O MODULES

All communication and I/O modules are shipped uninstalled in the drive.
It is the installers responsibility to install and configure the module and
associated field wiring (refer to drive manufacturers installation manual).
Catalog Number Suffix
CC
CD
CL
CP
CS
DI
DIO
RO
IF 1767 • 09/15
REM
L
(9)
(10)
R
POTENTIOMETER OPTION
(SUFFIX PT)
BLK
WHT
STOP
R
RED
STOP
BRN
(
)
FUSED DISCONNECT
SWITCH
L1
T1
L2
T2
L3
T3
BOTTOM SIDE OF SWITCH
TOP SIDE OF SWITCH
Description
CANOpen
DeviceNet
LonWorks
Profibus
SmartWire
240 VAC Input
3x DI, 3x DO, 24 VDC
Relay Output
Copyright
3
(1)
2
(2)
(3)
1
BLOWER AND FUSE BLOCK
(ENCLOSURE SIZES 2 AND 3 ONLY)
RED
RED
L1
T1
15A
L2
T2
15A
L3
T3
15A
YEL W/ GRN STRIPE
FUSE BLOCK

4. GENERAL OPERATION

4.1 CONTROL PAD VIEWING WINDOW

The control pad viewing window shows the control pad display
containing such information as drive status and operating data. Refer to
the drive manufacturer's manual for information regarding the control pad
display.
2015, Eaton's Crouse-Hinds Division
©
VARIABLE FREQUENCY DRIVE
/CONTROL MODULE
TRM
SIG
(1)
BLU
1
+10V
YEL
(2)
2
AI1+
RED
(3)
3
AI1-
4
AI2+
5
AI2-
6
GND
7
DIN5
8
DIN6
BLU
(9)
9
DIN7
(10)
YEL
10
DIN8
WHT
11
CMB
(12)
WHT
12
GND
RED
(13)
13
24Vo
(20)
14
DO1
RED
15
24Vo
WHT
16
GND
17
AO1+
18
AO2+
19
24Vi
BLU
20
DIN1
BRN
(21)
21
DIN2
22
DIN3
YEL
(23)
23
DIN4
WHT
24
CMA
25
A
26
B
RED
(27)
27
R3NO
BLK
(28)
28
R1NC
RED
29
R1CM
BLK
(30)
30
R1NO
RED
(31)
31
R3CM
32
R2NC
RED
33
R2CM
BLK
(34)
34
R2NO
STO+
STO-
L1
L2
L3
2
5
L1
BLOWER
L2
L3
GND
SIGNAL NAME
REF. OUTPUT VOLTAGE
ANALOG INPUT 1
ANALOG INPUT 1 GND
ANALOG INPUT 2
ANALOG INPUT 2 GND
I/O SIGNAL GROUND
DIGITAL INPUT 5
DIGITAL INPUT 6
DIGITAL INPUT 7
DIGITAL INPUT 8
DI5 - DI8 COMMON
I/0 SIGNAL GROUND
+24 VDC OUTPUT
DIGITAL OUTPUT 1
+24 VDC OUTPUT
I/0 SIGNAL GROUND
ANALOG OUTPUT 1
ANALOG OUTPUT 2
+24 VDC INPUT
DIGITAL INPUT 1
DIGITAL INPUT 2
DIGITAL INPUT 3
DIGITAL INPUT 4
DI1 - DI4 COMMON
RS-485 SIGNAL A
RS-485 SIGNAL B
RELAY 3 NORM. OPEN
RELAY 1 NORM. CLOSED
RELAY 1 COMMON
RELAY 1 NORM. OPEN
RELAY 3 COMMON
RELAY 2 NORM. CLOSED
RELAY 2 COMMON
RELAY 2 NORM. OPEN
SAFE TORQUE OFF
U
V
W
MOTOR/LOAD
GRN
Page 7