Safran MorphoAccess J Series Installation Manual page 30

Table of Contents

Advertisement

®
Section 3: Installation procedure
MorphoAccess
J Series – Installation Guide
3. Drill in the wall one hole with a diameter of 5mm and fit it with the rawplug
(see Figure 3.6). Hole centre can be located by placing the terminal's body on
the wall with its horizontal mounting holes facing the ones of the electric box.
4. Wire the necessary cables on the block connectors according to Section 4;
then plug the block connectors into the terminal blocks (6 on Figure 2.3).
5. Plug Ethernet cable (if present) into the RJ45 connector (5 on Figure 2.3).
6. Bring the terminal's body close to the wall, with the terminal's mounting
holes (2 on Figure 2.3) facing the 2 holes of the electric box (positioned
horizontally) and the hole drilled into the wall.
7. Fix the terminal's body with the M3X25 screw and the 2 screws coming
from the electric box (see Figure 3.6).
Figure 3.6: Terminal's body fixing
8. Switch on power supply from electrical source and confirm that the terminal
switches on (checking light from LED indicator and sound from buzzer).
9. At this stage, a USB mass storage key can be plugged into the terminal for
configuration (see Figure 3.7). For more details about product configuration
®
and setting, refer to MorphoAccess
J Series User Guide. Once configuration
is completed, remove the USB mass storage key.
22
DOCUMENT SSE-0000077503-04 - M
2011
ARCH
M
D
- R
ORPHO
OCUMENT
EPRODUCTION AND DISCLOSURE PROHIBITED