Anti-Pulling Switches - Safran MorphoAccess J Series Installation Manual

Table of Contents

Advertisement

®
MorphoAccess
J Series – Installation Guide

Anti-pulling switches

DOCUMENT SSE-0000077503-04 - M
M
D
- R
ORPHO
OCUMENT
EPRODUCTION AND DISCLOSURE PROHIBITED
See item 3 on figure 2.3 (section 2, paragraph 4)
These switches are activated as soon as there is enough pressure applied on the
terminal against the wall or the mounting spacer. They are deactivated as soon
as this pressure is not big enough, e.g. when the terminal is pulled out of the
wall.
When the switches are deactivated, the MorphoAccess
as required by the related configuration key (see MorphoAccess
Guide for key configuration description):
Ignore the event (default): usefull during normal maintenance operations.
Send an alarm message to the Central Access Controller, through the usual
channel of the access control result messages (Wiegand, DataClock,
RS485, Ethernet or Wi-Fi
block terminal «tamper switch pins», refer to paragraph 1 Wiring overview
and paragraph 3 Tamper switch.
Generate an audible alarm signal with the buzzer and a visual alarm signal
with the status LED.
2011
ARCH
Section 5: User Interface
®
TM
). The alarm signal is directly available on
J Series terminal acts
®
J Series User
57