Anti-Tamper And Anti-Pulling Switches Operating; Anti-Tamper Switches - Safran MorphoAccess J Series Installation Manual

Table of Contents

Advertisement

Section 5: User Interface
3. Anti-tamper and anti-pulling
switches operating

Anti-tamper switches

56
See item 5 on figure 2.2 (section 2, paragraph 3)
These switches are activated when the smoked front cover is plugged in.
Once activated, among the 2 terminal's USB ports, only the rear one is
functional (the front one is neither functional nor accessible, since recovered
by the smoked front cover).
Once the smoked front cover is unplugged, these switches become deactivated
and only the front USB port is functional (5 on Figure 2.2).
When the switches are deactivated, the MorphoAccess
as required by the related configuration key (see MorphoAccess
Guide for key configuration description):
Ignore the event (default): usefull during normal maintenance operations.
Send an alarm message to the Central Access Controller, through the usual
channel of the access control result messages (Wiegand, DataClock,
RS485, Ethernet or Wi-Fi
block terminal «tamper switch pins», refer to paragraph 1 Wiring overview
and paragraph 3 Tamper switch.
Generate an audible alarm signal with the buzzer and a visual alarm signal
with the status LED.
M
ORPHO
®
MorphoAccess
J Series – Installation Guide
TM
). The alarm signal is directly available on
DOCUMENT SSE-0000077503-04 - M
D
- R
OCUMENT
EPRODUCTION AND DISCLOSURE PROHIBITED
®
J Series terminal acts
®