Advanced Diagnostics
If a Digital Multimeter (DMM) is available then advanced troubleshooting can be performed for certain issues.
Mast cap
Mast assembly
Main Body of Machine
NO POWER/CONSOLE DOES NOT LIGHT UP
A. If voltage is not reaching the console, use the following multimeter tests to troubleshoot:
1. Check AC Adapter.
a. Set DMM to measure DC voltage.
b. Check voltage output from the AC Adapter.
• Connect positive probe on inside of connector plug and negative probe on outside of connector plug.
2. Check that voltage is reaching console.
a. Remove mast cap and disconnect the wiring connections.
b. Locate 12 Pin Plug coming from Mast Assembly.
c. Locate Purple and Pink Wires (see image).
d. Set DMM to measure DC voltage.
e. Connect positive probe to Pink Wire Pin 2.
f. Connect negative probe to Purple Wire Pin 1.
g. Voltage should be within 11-13VDC.
• If voltage is present, there is a break in the Wiring Harness within the console or it is not connected securely. Remove back of console to
inspect and reseat wire, or replace if damaged.
Console
2
(+) Pink Wire Pin 2
(-) Purple Wire Pin 1
12
30
1
11