Turning up a node
Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Turning Up a Node
• When a physical card type does not match the type of card provisioned for that slot in CTC, the card
might not boot and CTC will show a MEA (EQPT) alarm. If the card does not boot, open CTC and ensure
that the slot is not provisioned for a different card type before assuming that the card is faulty.
• If the red FAIL LED does not turn on, check the power.
• If you insert a card into a slot provisioned for a different card, all LEDs turn off.
• If the red FAIL LED is on continuously or the LEDs behave erratically, the card is not installed properly.
If any of these conditions are present, remove the card and repeat Steps
up properly the second time, contact your next level of support.
Step 7
If the card requires a Small Form-factor Pluggable (SFP, SFP+, XFP, CXP, or CPAK) or a C Form -factor
Pluggable (CFP) connector, complete one of the following tasks:
DLP-G723 Install PPM on a Line
CXP, CFP, or CPAK into the TXP, MXP, 100G-LC-C, 10x10G-LC, 100G-CK-C, CFP-LC, WSE,
GE_XP, 10GE_XP, GE_XPE, 10GE_XPE, ADM-10G, or OTU2_XP card.
DLP-G725 Preprovisioning PPM
SFP, SFP+, XFP, CXP, CFP, or CPAK and need to preprovision the SFP, SFP+, XFP, CXP, CFP, or
CPAK slot.
Note
Note
Step 8
If you need to remove an SFP, SFP+, XFP, CXP, CFP, or CPAK, complete the
from the Line Card
Note
Note
Stop. You have completed this procedure.
SFP, SFP+, XFP, CXP, CFP, and CPAK modules are hot-swappable input/output devices that
plug into a TXP, MXP, GE_XP, 10GE_XP, GE_XPE, 10GE_XPE, ADM-10G, OTU2_XP,
100G-LC-C, 10x10G-LC, CFP-LC, 100G-CK-C, or WSE line card port, to link the port with
the fiber-optic network. For more information, see the
GBIC, SFP, SFP+, and XFP Optics Modules in ONS Platforms
PPM provisioning determines how the SFP, SFP+, XFP, CXP, CPAK, and CFP modules are
used in CTC. PPM provisioning procedures are provided in the "Provision Transponder and
Muxponder Cards" chapter.
task.
You must provision the TXP, MXP, GE_XP, 10GE_XP, GE_XPE, 10GE_XPE, ADM-10G, or
OTU2_XP cards after you complete all node turn-up procedures. TXP and MXP provisioning
procedures are provided in Provision Transponder and Muxponder Cards.
Until a card is provisioned, the card is in the standby condition and the ACT/STBY LED remains
amber in color.
NTP-G179 Installing the Transponder and Muxponder Cards
Card—Complete this task to install the physical SFP, SFP+, XFP,
Slot—(Optional) Complete this task if you do not have the physical
3
to 5. If the card does not boot
Hardware Specifications
and the
documents.
DLP-G728 Remove PPM
Turning Up a Node
Installing
25