Turning Up a Node
Step 2
Click Add. The Add ANS Parameter dialog box appears.
Step 3
Select the ANS parameter from the Parameter drop-down list.
Step 4
In the Port Selection area, complete the following fields:
• Type—Displays the card type.
• Shelf—Choose the shelf from the drop-down list.
• Slot—Choose the card from the Slot drop-down list. The drop-down list lists all the cards that support
• Port—Choose the port from the Port drop-down list. The drop-down list lists all the ports for the card
Step 5
Choose the granularity as OTS or OCH from the Granularity drop-down list.
Note
Step 6
Type or choose the value for the ANS parameter in the Value field.
Step 7
Click OK.
Step 8
Return to your originating procedure (NTP).
DLP-G681 Modifying an ANS Parameter
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
Do not begin this procedure until the Cisco Transport Planner NE Update file is created for the node. You
must import the new NE Update file and run ANS to recalculate the ANS parameters for the node.
Caution
Modifying ANS parameters on one node requires ANS upgrades on all the other nodes within the network.
Do not begin this procedure until you are prepared to complete the upgrade on all the network nodes.
Caution
This procedure will affect the service of unprotected circuits that pass through the node.
the ANS parameter selected in Step 3.
selected in Step
4
that support the ANS parameter selected in Step 3.
Granularity can be set only for the ANS parameters applied to the LINE-RX, LINE-TX, COM-RX,
or COM-TX ports.
DLP-G681 Modifying an ANS Parameter
This task modifies ANS parameters.
None
DLP-G46 Log into CTC
As needed
Onsite or remote
Provisioning or higher
Turning Up a Node
15