Step 1
Choose Side A of the shelf to cable the 40-MUX-C and 40-DMX-C cards.
Note
Step 2
On the patch panel, locate the MPO cables and connectors.
Step 3
At the 40-MUX-C card in the node, plug the MPO connector labeled 1 RX on an MPO cable into the top
Add RX (30.3–35.8) port of the card.
Step 4
Plug the MPO connector labeled 2-RX into the Add RX (36.6–42.1) port on the card.
Step 5
Plug the MPO connector labeled 3-RX into the Add RX (42.9–48.5) port on the card.
Step 6
Plug the MPO connector labeled 4-RX into the Add RX (49.3–54.9) port on the card.
Step 7
Plug the MPO connector labeled 5-RX into the Add RX (55.7–61.4) port on the card.
Step 8
At the adjacent 40-DMX-C card in the same side of the shelf, plug the MPO connector labeled 1 TX on the
MPO cable.
Step 9
Plug the MPO connector labeled 2-TX into the Drop TX (36.6–42.1) port on the card.
Step 10
Plug the MPO connector labeled 3-TX into the Drop TX (42.9–48.5) port on the card.
Step 11
Plug the MPO connector labeled 4-TX into the Drop TX (49.3–54.9) port on the card.
Step 12
Plug the MPO connector labeled 5-TX into the Drop TX (55.7–61.4) port on the card.
Turning Up a Node
52
If you are cabling any cards from the right side of the shelf (Slots 12 through 17), you must first
perform the
DLP-G427 Rerouting Fiber-Optic Cables in the 40-Channel Patch Panel Tray, on page
43
to route the MPO cables out of the right side of the patch panel tray, or route the cables through
a fiber storage panel.
The cards and patch panels should already be installed
before you begin this procedure.
• One 40-MUX-C card per side of the mesh node
• One 40-DMX-C card per side of the mesh node
• One 40-channel patch panel trays per side of the
mesh node, preinstalled with MPO cables (each
MPO cable is terminated on one end with one
MPO connector and on the other end with eight
LC-type connectors)
NTP-G34 Installing Fiber-Optic Cables on DWDM
Cards and DCUs, on page 27
DLP-G427 Rerouting Fiber-Optic Cables in the
40-Channel Patch Panel Tray, on page 43
As needed
Onsite
None
Turning Up a Node

Advertisement

Table of Contents
loading

Table of Contents