ESAB CIGWELD CutSkill 60 Operating Manual page 41

Table of Contents

Advertisement

PROBLEM
4
Electrode or cutting
tip installation error
5
Voltage error
6
Over temperature
error
0-5574
OPERATING MANUAL
CAUSE
A
Electrode or tip is not installed
correctly.
B
Electrode or tip is seriously
worn.
C
Plasma torch failure.
D
Power source component
failure.
A
The mains supply voltage out
of range.
B
Power source component
failure.
A
Duty cycle of power source has
been exceeded.
B
Air flow through or around the
unit is blocked.
C
Fan failure
D
Power source component
failure.
5-3
CutSkill 60
REMEDY
A
Reinstall the electrode or tip.
B
Replace worn electrode or tip.
C
Have an accredited CIGWELD
service provider repair or replace.
D
Have an accredited CIGWELD
service provider repair or replace.
A
Check if the input voltage is within
204~276.
B
Have an accredited CIGWELD
service provider repair or replace.
A
Leave the power source switched
ON and allow it to cool. Note that
Over Temperature Error screen
must be extinguished prior to
commencement of cutting.
Keep the ventilation clearance.
B
C
Check if the fan is turnning when
the main switch is ON. Have an
accredited CIGWELD service
provider repair or replace if the fan
is not working.
D
Have an accredited CIGWELD
service provider repair or replace.
SERVICE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1-1601-60

Table of Contents