5. Electrode or Cutting/Gouging Tip Installation Error Screen
Electorde or Cutting/Gouging Tip Installation Error Screen displays when the electrode or cutting/gouging tip
is not installed correctly. Gas will flow for 2 seconds then stop for 3 seconds. The power source continues
to check the status of electrode and cutting/ gouging tip until they are in correct position. Please turn off the
power source and check or replace the worn tip or electrode.
Figure 2-19: Electrode or Cutting/Gouging Tip Installation Error Screen
6. Air Pressure Error Screen
Air Pressure Error Screen displays when the output air pressure is less than 400kPa or more than 600kPa.
Adjust the pressure of input compressed air to correct level until the error alarm is clear.
7. Voltage Error Screen
Voltage Error Screen displays when the input voltage is too low or PFC circuit fails. Contact Accredited Cigweld
Service Provider for repair if necessary.
0-5574
OPERATING MANUAL
Figure 2-20: Air Pressure Error Screen
Figure 2-21: Voltage Error Screen