Sequence Of Operation - ESAB CIGWELD CutSkill 60 Operating Manual

Table of Contents

Advertisement

4.02 Sequence of Operation

The following is a typical sequence of operation for this power supply. Refer to Appendix 1 for block diagram.
1. Plug the input power cord into an active circuit.
2. Switch the ON / OFF switch on the rear panel of the power source to ON position. Ensure the LCD illumi-
nates.
3. Select trigger mode between 2T and 4T. Refer to 2.05.3 for details.
4. Select cutting mode among Plate Mode, Gouging Mode and Grid Mode. Refer to 2.05.3 for details.
NOTE
Please note that when trigger mode is set at 4T, both gouging mode and grid cutting mode are unavailable.
5. Check air pressure. Press the Control Knob and enter gas purge menu (refer to Section 2.05.3) to turn
on gas purge function. The gas flows and the screen displays air pressure. Make sure the pressure is in
the correct range from 410 kPa to 550 kPa. Please note the power source has set gas pressure to 460
kPa as default value. Press the Control Knob again to stop gas flow.
6. Select Home icon and press the Control Knob to exit the menu screen.
7. Adjust output current value via control knob on the front control panel (refer to Section 2.04.2).
8. Wear protective clothing, including welding gloves and appropriate eye protection (see Table 1-1).
0-5574
OPERATING MANUAL
Figure 4-4: Selecting Trigger Mode
Figure 4-5: Selecting Cutting Mode
4-3
CutSkill 60
OPERATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1-1601-60

Table of Contents