Additional fuses
Backup fuse (type NH gG) ......................... 3 x 20 A
Connection cross-section .......................... 2.5 mm
Backup fuse ............................................... 16 A to 20 A (setting value: 20 A)
(Automatic line fuse, e.g. Siemens 3VL1702-1DD33)
Connection cross-section .......................... 2.5 mm
Total weight (approx.) ................................ 300 kg
2.2.4
R&S NV8304
Number of amplifiers ................................. 4
with MER 34 dB .............................. 1720 W
P
out
with MER 33 dB .............................. 1800 W
P
out
Air flow rate ................................................ At least 17 m
Power consumption (worst case) .............. 10.0 kW with P
Heat dissipation ducted (worst case) ......... 7.2 kW
Heat dissipation to surrounding air ............ approx. 500 W
Additional fuses
Backup fuse (type NH gG) ......................... 3 x 25 A
Connection cross-section .......................... 4.0 mm
Backup fuse ............................................... 25 A to 32 A (setting value: 25 A)
(Automatic line fuse, e.g. Siemens 3VL1703-1DD33)
Connection cross-section .......................... 4.0 mm
Total weight (approx.) ................................ 325 kg
2098.0188.72
Chapter 2
2
/ AWG 10
2
/ AWG 10
2
/ AWG 10
2
/ AWG 10
- 2.34 -
Design and Characteristics
3
/min
outmax
E-1