The FH 825 harmonics filter is used to suppress harmonics. It is a 23rd order Chebyshev
filter which uses coaxial technology so that it is suitable for the rigid line system 13-30. On
the signal path, the harmonics filter is located directly downstream of the combiner.
The harmonics filter is varnished to reduce the surface temperature.
Note
Transmitters with one amplifier in rack
In transmitters having only one amplifier in the rack, the harmonics filter is connected direct-
ly with the RF output of the amplifier via a coaxial cable.
1.8

RF Connector

Fig. 29 RF connector
The RF connector (1
ferred).
2098.0188.72
Chapter 2
5
/
" EIA flange) is located on the transmitter roof (or under it if pre-
8