R&S N 8000 Series System Manual page 64

Dtv transmitters atsc
Table of Contents

Advertisement

The rack controller is used to monitor, control, and protect the transmitter rack. It handles
the following functions:
Keeps the transmitter running if the R&S NetCCU800 fails
Controls data exchange between the R&S NetCCU800 and other components via CAN
bus
Monitors the outlet air temperature
Acquires measured data about the intake and outlet air temperatures
Transfers messages
Accepts and outputs rack commands (e.g. transmitter ON -> amplifier ON, cooling sys-
tem ON)
Configures the test points (mode-dependent)
Switches off the rack in the event of malfunction (e.g. fan failure)
The following equipment and modules can be connected to the rack controller:
R&S NetCCU800 via CAN bus
Exciters (1 or 2)
External cooling system (liquid-cooled transmitters)
Amplifier stages (1 or 2)
Power distribution
Temperature sensors
Power test points
The rack controller cannot be operated directly. It is operated via the R&S NetCCU800.
Note
2098.0188.72
Chapter 2
- 2.12 -
Design and Characteristics
E-1