START-UP AND OPERATION / TEMPERATURE SETTINGS / THERMOMETER
1. Case Start-Up
Plug cord into a certified electrical outlet with
ground.
Turn on the Main Power Switch. Switch is in the
Drop-In Refrigerated Section on the rear right
hand side of base.
The Temperature Control Module (LED) will
illuminate. Evaporator coil fans and the
compressor motor should turn on.
From the front of the case, raise deck to confirm
that the coil fans are functioning properly.
Turn on the lights. Light Switch is in the Upper
Display interior of the case at rear right side
(see illustration at right).
First time lighting may require a short warm up
period for the bulbs. Slightly dim or a flickering
of new bulbs is normal.
Spirit-Filled
Thermometer
Drop-In
Refrigerated
Section
Magnetic Filter (For Internal
Condensate Package)
2. Temperature Settings
This case has been tested to maintain a
temperature at or below 41 °F (5 °C)
When the merchandiser is in a start-up mode or
has been idle for a long period of time, the unit
requires 30 minutes in order to pull-down to
temperature.
Spirit-filled thermometer located in refrigerated
compartment is for monitoring warmest air
temperature in accordance with NSF® Std. 7.
The temperature is controlled by a temperature
control module. It is located at the lower-right
area (from case rear) of the drop-in refrigerated
section. See below for general location.
If a temperature setting change is required,refer to
instructions in the temperature controller section
of this operating manual.
Light Switch Inside
(at Top of Plenum)
Glass Shelf
Deck
9
Upper Display
Case
Main Power
"Rocker" Switch
ON
OFF
—– Main Power "Rocker"