READ AND SAVE THESE INSTRUCTIONS
SCC P/N
INSTALLATION &
®
20-42840
OPERATING MANUAL
M O B I L E
S E R I E S
Oasis® 32" Deep Non-Refrigerated Self-Service In-Aisle Grab-N-Go Wall Units
Model B4732DShown Without
Model B4732 Shown With
Optional Roll-Down Security Cover
Optional Roll-Down Security Cover
:
:
:
:
:
*Lengths include end panels.
888 E. Porter Road · Muskegon, MI 49441 Phone: 231.798.8888 Fax: 231.798.4960 www.structuralconcepts.com
Rev B Date: 6.11.2016
I:\Oper Manuals\Oasis\B4732D_In_Aisle_Ambient_Wall_Unit_20-42840.pub

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Oasis Mobile Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Structural Concepts Oasis Mobile Series

  • Page 1 READ AND SAVE THESE INSTRUCTIONS SCC P/N INSTALLATION & ® 20-42840 OPERATING MANUAL M O B I L E S E R I E S Oasis® 32” Deep Non-Refrigerated Self-Service In-Aisle Grab-N-Go Wall Units Model B4732DShown Without Model B4732 Shown With Optional Roll-Down Security Cover Optional Roll-Down Security Cover *Lengths include end panels.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS / MODELS and DIMENSIONS OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING / PLUGS ..………..INSTALLATION: CASE REMOVAL / POSITIONING & ALIGNING CASE .…………………………….. FRONT PANEL ACCESS / MAIN POWER SWITCH ………………………………………………………. POWER CORD / FIELD ACCESS & ELECTRICAL BOX / BALLASTS ………………………………… LIGHT FIXTURES - T8 FLUORESCENTS …………………………………………………………………...
  • Page 3: Overview / Type / Compliance / Warnings / Precautions / Wiring / Plugs

    If unsure if unit is designed for Type 1 or 2, see tag next to serial label. See SERIAL LABEL LOCATION  These Structural Concepts merchandisers are & INFORMATION LISTED / TECH INFO & SERVICE designed to merchandise packaged products at section in this manual for sample serial labels.
  • Page 4: Installation: Case Removal / Positioning & Aligning Case

    INSTALLATION: CASE REMOVAL / POSITIONING & ALIGNING CASE 2. Remove Case From Skid (Casters) 1. Remove Case From Skid (Levelers) Remove shipping brackets that may be securing  Remove shipping brace that may be securing casters to skid case to skid. ...
  • Page 5: Front Panel Access / Main Power Switch

    FRONT PANEL ACCESS / MAIN POWER SWITCH  Turn on main power switch (located on main 1. Front Panel ballast box) below controller.  Front panel can be removed from case by simply  Return front panel to case after main power lifting up and off.
  • Page 6: Power Cord / Field Access & Electrical Box / Ballasts

    POWER CORD / FIELD ACCESS & ELECTRICAL BOX / BALLASTS Warning! Disconnect power before providing maintenance and service to unit. Power Cord / Field Access / Electrical Box / Ballasts  Power cord exits case at rear.  Field access box is accessible at case rear by removing rear panel. Four (4) screws must be removed from panel (as shown below) to separate from case.
  • Page 7: Light Fixtures - T8 Fluorescents

    LIGHT FIXTURES - T8 FLUORESCENTS 1. Light Fixtures - T8 Fluorescents Removal of lamp:  Rotate lamp (1/4-turn) either direction to Warning! Disconnect power before providing disengage (upper or lower) pins/contacts from maintenance and service to unit. lamp-mounting sockets. Caution: Lights have been treated to resist ...
  • Page 8: Light Fixtures - Leds

    Removal / Replacement of LED Light Fixtures LED’s Removal of lamp: Oval Form  LED lights rarely require change-out.  Contact Structural Concepts’ Technical Service Department for replacement parts (see the Technical Service section of operating manual). Plug’s Oval Form Light Fixture...
  • Page 9: Optional Roll-Down Security Cover

    OPTIONAL ROLL-DOWN SECURITY COVER Roll Down Security Cover (Optional): Shown Extended  Optional roll down security cover has two handles for grasping, lowering and raising.  After roll-down cover is lowered, key may be turned clockwise to lock latch into strike bracket. ...
  • Page 10: Cleaning Schedule (To Be Performed By Store Personnel)

    CLEANING SCHEDULE - TO BE PERFORMED BY STORE PERSONNEL AREA TO CLEAN FREQUENCY INSTRUCTIONS Case Exterior Daily Sneeze Guard: Clean with a warm water and mild soap solution and soft cloth. Never use ammonia-based cleaners on acrylic. Daily End Panels / Front Panels / Header / Optional Roll-Down Security Cover: Clean with a warm water and mild soap so- lution and soft cloth.
  • Page 11: Troubleshooting (To Be Performed By Trained Service Providers Only)

    TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY) CONDITION TROUBLESHOOTING Case Not Lining Up See Installation section in this manual for instructions on properly aligning case (alongside other cases) and adjusting levelers. System Not Check that the utility power is on. Operating Check that the MAIN power switch is on.
  • Page 12: Serial Label Location & Information Listed / Tech Info & Service

    For additional technical information and service, see the TECHNICAL SERVICE page in this  manual for instructions on contacting Structural Concepts’ Technical Service Department. manual for instructions on contacting Structural Concepts’ Technical Service Department. See images below for samples of both refrigerated and non-refrigerated serial labels.
  • Page 13: Technical Service Contact Information & Warranty Information

    LIMITED WARRANTY All sales by Structural Concepts Corporation (SCC) are subject to the following limited warranty. “Goods” refers to the product or products being sold by SCC. Warranty Scope: Warranty is for equipment sold in the United States, Canada, Mexico and Puerto Rico. Equipment sold elsewhere may carry modified warranty.

This manual is also suitable for:

B4732dB3632dB5932dB7132dB8832d

Table of Contents