Troubleshooting Guide - Landoll 2110 Operator's Manual

Coulter chisel
Hide thumbs Also See for 2110:
Table of Contents

Advertisement

TROUBLESHOOTING GUIDE

The Troubleshooting Guide, shown below, is included to help you quickly locate problems that can hap-
pen using your 2110 Coulter Chisel. Follow all safety precautions stated in the previous sections when mak-
ing any adjustments to your machine.
PROBLEM
UNIT NOT PULLING EVEN
UNEVEN DEPTH
UNIT SIDE DRAFTS OR MOVES SIDE TO SIDE
SHANKS PLUGGING WITH RESIDUE
BACK ROW OF SHANKS PLUGGING WITH
RESIDUE
SHANKS NOT PENETRATING
WHEEL BEARING FAILURE
HYDRAULIC - COULTER LIFT CYLINDERS NOT
FULLY EXTENDING
PROBABLE CAUSE:SOLUTION
Coulter gangs uneven depth: adjust
depth/rephase coulter gang cylinders. See
"Hydraulic Coulter Gang Lift System" on page 4-4.
Unit not level when under power in the field: level
unit front to rear. See "Leveling (Front To Rear)" on
page 4-5.
Excessive coulter gang depth or down pressure:
reduce coulter depth.
Tire pressure too low: check inflation.
Unit not level front to rear: adjust unit to be level.
Lift wheels not carrying enough weight: adjust
depth stop and raise implement.
Unit not level front to rear: adjust unit to be level.
Unit not level: level machine. See "Leveling (Front
To Rear)" on page 4-5.
Coulters not cutting residue: adjust coulter depth.
Twisted shovels throwing soil wrong direction:
Install shovels as shown in Figures 2-1 - 2-10.
Heavy residue: install optional offset shank mounts
to stagger back row of shanks. See "Offset Shank
Mount Installation" on page 3-22.
Unit not level: level unit front to rear. See "Leveling
(Front To Rear)" on page 4-5.
Excessive coulter depth: reduce depth
Points worn: install new points.
Triple-lip seals not installed correctly: install seals
with the lips pointing outward away from the hub.
Lift cylinders not in phase: fully extend cylinders
and hold hydraulic lever until all cylinders are fully
extended.
Cylinders not installed in proper series: Wing
cylinders are smaller diameter than center cylinders.
Reinstall cylinders properly.
Hoses not properly connected: check hose routing
5
5-1

Advertisement