Hazards That May Be Encountered In The Electric System - Sacmi BTA 900 Instruction Manual

Knurling machine for aluminum caps, cutting machine for plastic caps
Table of Contents

Advertisement

166.07
.A02
SAFETY EQUIPMENT AND PRECAUTIONS
3
RISKS PRESENT IN THE PRODUCT HANDLING SYSTEM
WARNING!
E0004P
The product handling system exposes the operators to the following risks, as they may accidentally come into
contact with moving parts:
hands and/or limbs may be crushed, caught and dragged and cut off.
DURING OPERATION
The handling system inside the machine presents no risks for the operators as it is fully protected by interlocked guards.
The machine immediately stops if one of these guards is opened while the machine is running.
DURING MAINTENANCE
The guards have to be opened, taking all the precautions indicated in the maintenance chapter, when maintenance
is carried out. The guards must be closed as soon as maintenance has been completed.
ADDITIONAL RISKS
Precautions to be taken.
- When turning the drums in manual mode make sure your hands are out of the way of moving parts.
- Always make sure that other persons (operators - maintenance men) do not have their hands near or in the area of
moving parts (manual operation) or are inspecting parts that can be operated in manual mode.
Failure to observe these precautions may cause your hands and/or limbs to be crushed, caught and dragged and even
cut off.
The risk of being crushed is indicated by signs placed inside the guards in the machine.
3.5.2

HAZARDS THAT MAY BE ENCOUNTERED IN THE ELECTRIC SYSTEM

SWITCHBOARD: DANGER OF COMING INTO CONTACT WITH LIVE PARTS.
The switchboard can be accessed even if power is being supplied to the system. As called for by the EN 60204-1
standard, it can be accessed only with a key or other specific tool. These tools must be given exclusively to authorized
personnel who are highly qualified and specially trained to access live parts.
WHEN POWER IS BEING SUPPLIED TO THE SWITCHBOARD THE QUALIFIED PERSONNEL WHO HAVE BEEN
AUTHORIZED CAN ONLY RESET THE SAFETY EQUIPMENT.
WARNING!
E0004P
Whenever a component either inside or outside the switchboard has to be replaced, the maintenance man must
shut off the system with the main switch and padlock it in its open position to prevent it from being started up
accidentally.
FIREFIGHTING EQUIPMENT
The following must be provided by the customer in the area where the machine is installed
- a firefighting system that complies with the laws in force in the country where the machine is installed.
3 - 8