Advanced EDID Management: using EDID Router

Each DVI sink ( eg. monitors, projectors, plasma displays, switcher inputs) must
support the EDID data structure. Source BIOS and operating systems are likely to
query the sink using DDC2B protocol to determine what pixel formats and interface
is supported. DVI standard makes use of EDID data structure for the identification
of the monitor type and capabilities. Most DVI sources (VGA cards, set top boxes,
etc) will output DVI signal after accepting the connected sink's EDID information. In
case of EDID readout failure or missing EDID the source will not output DVI video
signal.

7.1 Why is EDID management necessary?

All DVI sources must read attached sink's EDID data (switcher input, monitor input,
etc.) before starting the DVI signal transmission. If no EDID is available, most
sources will not output the signal. Unlike in standard analog VGA graphics cards,
DVI
desktop/properties/settings tab to different pixel resolutions. Only those resolutions
and refresh rates are allowed, which are defined in EDID data.
To provide proper EDID data for DVI sources MX32x32DVI-Pro has an Advanced
EDID Manager, that can manage the emulated EDID on its all inputs indpendently.
EDID can be managed using Lightware Matrix Controller software from a PC
computer or Laptop through RS232 connection or Ethernet port. Emulating the
right EDID information helps the user and installation engineer to control overall
system's signal properties
EDID emulating options are:
With EDID Router function the user is able to store EDID from any attached
monitor to one of the user programmable memories, to download EDID from file to
user memory, and to upload EDID from the router to file.
Info
User must not disconnect DVI cables to change an EDID opposite to other
manufacturer's products. EDID can be changed even if source is connected to the
input and powered ON .
Info
When EDID has been changed, the router toggles the HOTPUG signal for 200
msec. Some graphic cards or DVD players do not sense the hotplug signal, and
there can be happen, that even if EDID has been changed, the new set resolution
is not affected. This case the source device must be restarted, or powered OFF
and ON again.
Page 60 / 79
graphics
cards
do
Memory EDID emulation:
preset memory ( 50 EDID from 01 to 50). The selected EDID is
emulated at the desired ( or all) DVI inputs.
User memory EDID emulation:
preset memory ( 50 memory locations from 51 to 100) The
selected EDID is emulated at the desired ( or all) DVI inputs.
Dynamic EDID emulation3
of attached display devices The EDID of the attached display
device ( projector, moitor, etc) is emulated on the desired input. If
the display is changed, and new device is attached, the EDID on
selected inputs will automatically be changed according to the new
display.
not
allow
to
be
static EDID emulation from factory
static EDID emulation from user
copying and emulating EDID from one
forced
from
Windows

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx16x16dvi-pro

Table of Contents