Save Preset To The Specified Memory Location; Load Preset From The Specified Location; Reload Factory Default Pll Setup - Lightware MX32x32DVI-Pro User Manual

Table of Contents

Advertisement

3.1.10
location
Description:Save current ties to preset zz.
Example:Save current connections to preset memory 7.
Info:
The router saves the mute state of the outputs as well.
Info:
Lock states are not saved. Lock state is assigned to the physical output of the
router. Presets don't affect output locks.
3.1.11
Description: Load preset zz.
.
Example: Load connections previously saved to preset
memory 7. All connections will be reloaded.
Info:
The router loads the mute state of the outputs as well.
Info:
Lock states are not loaded. Lock state is assigned to the physical output of the
router. Presets don't affect output locks.
3.1.12
Description:
factory default PLL setup
to all outputs.
Example:
Legend: P1..P7 are the default parameters for the particular output.
Page 26 / 79
Save preset to the specified memory

Load preset from the specified location

Reload factory default PLL setup

Reloads
Command
{r00}
Response
(DVP●P1●P2●P3●P4●P5●P6●P7)CrLf
{r00}
(DVP 37 80 88 0D 34 00 05 )CrLf
Command
{$zz}
Response
(SPRzz)CrLf
{$07}
(SPR07)CrLf
Command
{%zz}
Response
(LPRzz)CrLf
{%07}
(LPR07)CrLf

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx16x16dvi-pro

Table of Contents