Guidelines for changing NetBackup appliance FT target ports to receive data streams from multiple SAN Client
Guidelines for changing NetBackup appliance FT
target ports to receive data streams from multiple
SAN Client FC initiator ports
You can also use the
Manage > FC Show
of the SAN Client feature. From the output that you receive after you have run the
command, you can verify the following:
Manage > FC Show
The
and
qla2xxx
The target ports are in
type is
Target(FTMS)
Under the Status column, the target mode ports should have a status of Fabric
if the port is physically connected to something such as a switch
Nothing ever appears under the Remote Ports column for target mode ports.
To find more information about the target mode ports, you must look at the VxUL
logs for the originator 199 (
If you want an appliance Fibre Transport (FT) target port to handle data streams
from more than two SAN client Fibre Channel (FC) initiator ports concurrently,
consider changing the following NetBackup master server setting:
nbftconfig –setconfig –ncp 4
Caution: This setting applies to all target ports on all FT media servers in your
NetBackup domain. This setting should only be increased from the default (2) when
all of the following conditions exist:
All FT target ports on all FT media servers are eight gBit/s link speeds.
The total mix of FT jobs is such that all of the FT media servers have unused FT
pipes.
A large number of jobs from other SAN Client machines are waiting for resources.
The back-end storage units have a lot of unused throughput capacity.
If you increase the
–ncp
media servers when all SAN Client machines are zoned to all FT media servers
could become highly imbalanced.
Configuring Fibre Transport on the appliance
command to verify and confirm the status
drivers are loaded.
windrvr6
mode by physical state, and their configuration
Target
).
nbftsvr
setting too high, the load balancing between multiple FT