MLA System
USER GUIDE
This is particularly useful for example giving you the option to EQ an MLD down fill independently from the rest of the array but
ensuring that the EQ is matched on both left and right arrays.

X-Array Ganging

X-Array gangs are groups of a single parameter in any included arrays. X-Array ganging is not possible on arrays or zones that are
already ganged. In this example we will gang only the high pass filter on all four arrays of the previous system example. With the
ganging tab for one array selected, click on the parameter we wish to gang in the X-Array Filter Ganging section. If there is already
an upper level gang (array or zone) in use you will see the following window;-
You will need to remove any gangs by clicking again on the array name or zone number boxes. Once this is done, click on the
parameter again, you will see this window;-
MLA System User Guide V2.1
284