USER GUIDE
This enables two options for connected cabinets. The first is to run temperature monitoring for all amplifier and DSP modules
displayed in the array windows. These display two temperatures, the hottest of the amplifier modules, the module concerned
indicated by a number from 1 to 3 for MLA and MLA Compact (the amplifier modules are two channel). The second value is the
temperature of the module DSP section. This can be disabled to speed up network traffic for large, complex systems.
User Interface: The final option in the Preferences window is User interface;-
This allows customisation of certain functions within the application.
Increment Values;-
These allow the default increment values for both Gain and Delay to be changed as required. The default for Gain is 0.5dB but
the options are for increments of 0.1, 0.2, 0.25, 0.5 or 1dB.
For delay, the default is 25ms, the options are 0.1, 0.2, 0.25, 0.5 or 1ms.
EQ Graph controls how the various parametric EQ filters are displayed in the array and Merlin windows;-
By default the graph will display the selected filter band that is being adjusted and the overall frequency response which keeps
the display from getting too cluttered. If you un-check the box the response of every active filter is displayed individually as well
as the overall response.
The Windows Power Option;-