A. Technical appendix
Operating voltage
Electronics
Pin 1
Operating voltage connection
- rated value
- tolerance
Current consumption
- pin 1 node FB8
- complete electronics of CP system
Residual ripple
Bridging time during failure
of logic voltage
Operating voltage of
solenoid valves on CP terminal
Pin 2
Operating voltage connection
- rated value
- tolerance
Current consumption
• pin 2 node FB8
Residual ripple
Bridging time during failure of logic voltage
A-4
DC 24 V
DC 18 .. 30 V
200 mA
see "CP system" manual,
chapter 3.1.2, Current consumption table
4 Vpp (within tolerance)
20 ms (min.)
DC 24 V
20.4 .. 26.4 V
Sum of all switched-on
CP solenoid valves;
see "CP pneumatics" manual
4 Vpp (within tolerance)
20 ms (min.)
CP FB8 9809a