DWU951 (DD1-WU80P/81P) / DWX951 (DD1-WX80P/81P) / DXG1051 (DD1-X100P/101P)
4-2 AIR SENSOR adjustment
When you replaced the MAIN PCB, SENSOR-A/
B PCB or BALLAST FAN, or when you re-
DWWDFKHG RQH RI WKH %$//$67 +2/'(5V PDNH
sure to carry out this adjustment after
re-assembling the projector and cleaning the air
¿OWHU
A-SENS bar
A-SENS
>>EXE 1:xxxx
4-3 INDEX DELAY adjustment
Test pattern for the adjustment
Red (255/255)
CW-BRI bar
CW-BRI
139
CW-CLR bar
CW-CLR
338
(You do not have to care the numbers in these
menus.)
DWU951/DWX951/DXG1051 Service Manual
020-000674-01 Rev.1 (01-2014)
2:xxxx
3:xxxx
4:xxxx
END
Adjustment procedure
1. Display the A-SENS bar with the
buttons in FACTORY MENU - VID-AD1.
2. Press the
button to run automatic adjustment
program. The cell END is highlighted in about 5
PLQXWHV DIWHU WKH DGMXVWPHQW ¿QLVKHG
3. When one of the values in the cell is out of
SURSHU UDQJH VHH EHORZ  FKHFN WKH SRVLWLRQ DQG
connection of each part.
1: 3700 ~ 4900 2: 3400 ~ 4400
3: 3000 ~ 3850 4: 2550 ~ 3250
Adjustment procedure
1. Open the ADVANCED MENU and set the
COLOR WHEEL in IMAGE SETTINGS menu to
BRIGHT.
2. Open the FACTORY MENU and display the CW-
%5, EDU ZLWK WKH
MENU - DLP.
3. 0RYH WKH FXUVRU WR WKH FHOO RQ WKH ULJKW DQG WDNH
notes of the values when horizontal stripes appear
as both of increasing and decreasing the value.
4. Set the value in the middle of the values.
Ex.: The horizontal stripes appear at the value X
as increasing the value and the value Y as
decreasing, set the value to (X+Y)/2.
5. Open the ADVANCED MENU and set the
COLOR WHEEL in IMAGE SETTINGS menu to
RICH COLOR.
6. Open the FACTORY MENU and display the CW-
&/5 EDU ZLWK WKH
MENU - DLP.
7. Set the value in the same way as CW-BRI, step 3
and 4.
7
and
DQG
EXWWRQV LQ )$&725<
DQG
EXWWRQV LQ )$&725<
Page 7 / 118

Advertisement

loading