3. Connect CNHS. Bandle LAMP2 UP FAN cable, temperature sensor cable and CNCWC with the
ferrite core, and connect them.
4. Style CNCS2, and
connect CNCS2 and CNCS1.
5. Style and connect CNDML.
Make sure no wire rests on the
top of the boss to avoid pinching
with the UPPER CASE.
Do not pass any wire through
the curve of CNDML.
DWU951/DWX951/DXG1051 Service Manual
020-000674-01 Rev.1 (01-2014)
Do not let CNCS2 and CNDMC
touch the LAMP1 HOUSE.
LAMP1 CASE
Wind CNCS2 around CNDMC two and
a half times in counter-clockwise before
connecting to the MAIN PCB.
58
Bundle LAMP2 UP FAN cable, temperature sensor cable
and CNCWC with the ferrite core. Fasten the core with a
cable tie. Be sure to turn the tie to the PCB.
CNDMC
Connect CNHS.
LAMP2 UP FAN cable.
Connect temperature
sensor cable.
Connect CNCWC.
Connect CNCS2.
Connect CNCS1.
Connect CNDML.