VAT 615 Series Installation, Operating, & Maintenance Instructions page 82

Dn 40 (i.d. 1 1/2”), devicenet, butterfly control & isolation valve with extended control range, with devicenet interface
Table of Contents

Advertisement

14. Push in the o-ring equally around the plate
into o-ring groove
15. Plate with equal mounted o-ring
16. Place the plate on the shaft in the valve
body
17. Tighten plate screws to block.
18. Loosen the plate screws a quarter turn
counter clockwise.
Fact: Plate is now movable on shaft and ready
to sliding into valve seat. Proceed with step 19.
19. Connect electrical POWER connection at
valve
Attention!
Valve does synchronize automatically
and moves the plate into sit of valve
body (close position).
20. Disconnect electrical POWER connection
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½"), DeviceNet
Description
Attention!
Keep fingers out of the valve
opening during plate movement!
Required tool
Allen Wrench
3mm
603476EA
82/102
2013-07-25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

61532-keaq-0001

Table of Contents