VAT 615 Series Installation, Operating, & Maintenance Instructions page 66

Dn 40 (i.d. 1 1/2”), devicenet, butterfly control & isolation valve with extended control range, with devicenet interface
Table of Contents

Advertisement

Command
UPLOAD
LEARN DATA
DOWNLOAD
LEARN DATA
SYNCHRONIZATION
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½"), DeviceNet
Service Code
Class ID
50
48
X:
index (000 .. 103, whereas these indices must be ASCII coded,
e.g. 000 = 30h 30h 30h, 001 = 30h 30h 31h, etc.)
This command loads the learn data sets from the valve up to the host. There are a total
number of 104 data sets which need to be uploaded separately. Each answer consists of 11
bytes. Whereas the leading 3 bytes are the data set index followed by 8 data bytes. Data are
ASCII coded.
51
48
X:
index (000 .. 103, whereas these indices must be ASCII coded,
e.g. 000 = 30h 30h 30h, 001 = 30h 30h 31h, etc.)
Y
8 data bytes ASCII coded (e.g. 30h 32h 33h 33h 33h 30h 33h 36h)
Example of XY: 30h 30h 30h 30h 32h 33h 33h 33h 30h 33h 36h (11 bytes in total)
This command loads the learn data sets from the host down to the valve. There are a total
number of 104 data sets. Each data set needs to be downloaded separately.
52
48
X:
C:8202 (string)
This tunnel command starts the synchronization of the valve.
Instance ID
Attribute ID
Description
1
1
1
synchronize valve
Service
data length
(number of
bytes)
-
11
12
1
-
6
603476EA
2013-07-25
Service
data field
XY
X
66/102