VAT 615 Series Installation, Operating, & Maintenance Instructions page 71

Dn 40 (i.d. 1 1/2”), devicenet, butterfly control & isolation valve with extended control range, with devicenet interface
Table of Contents

Advertisement

Command
PID CONTROLLER
GAIN FACTOR
PID CONTROLLER
SENSOR DELAY
PID CONTROLLER
SETPOINT RAMP
LEARN
LEARN
PRESSURE LIMIT
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½"), DeviceNet
Service Code
Class ID
Set
16
51
Get
14
X:
0 = 0.10, 1 = 0.13, 2 = 0.18, 3 = 0.23, 4 = 0.32, 5 = 0.42, 6 = 0.56
7 = 0.75, 8 = 1.00, 9 = 1.33, 10 = 1.78, 11 = 2.37, 12 = 3.16, 13 = 4.22
14 = 5.62, 15 = 7.50, 16 = 0.0001, 17 = 0.0003, 18 = 0.001, 19 = 0.003,
20 = 0.01, 21 = 0.02, 22 = 0.05
This command selects/returns the gain factor for the PID controller.
Note: Refer to «Gain factor adjustment» for details.
Set
16
51
Get
14
X:
0 = 0, 1 = 0.02, 2 = 0.04, 3 = 0.06, 4 = 0.08, 5 = 0.10, 6 = 0.15
7 = 0.20, 8 = 0.25, 9 = 0.30, 10 = 0.35, 11 = 0.4, 12 = 0.5, 13 = 0.6
14 = 0.8, 15 = 1.0
This command selects/returns the sensor delay for the PID controller.
Note: Refer to «Sensor delay adjustment» for details.
Set
16
51
Get
14
X:
0 = 0, 1 = 0.5, 2 = 1.0, 3 = 1.5, 4 = 2.0, 5 = 2.5, 6 = 3.0
7 = 3.5, 8 = 4.0, 9 = 4.5, 10 = 5.0, 11 = 5.5, 12 = 6.0, 13 = 6.5
14 = 7.0, 15 = 7.5, 16 = 8.0, 17 = 8.5, 18 = 9.0, 19 = 9.5, 20 = 10.0
This command selects/returns the setpoint ramp for the PID controller.
Note: Refer to «Setpoint ramp adjustment» for details.
99
51
This command starts LEARN.
With CONTROL MODE commands open valve or close valve the routine may be interrupted.
Note: Without LEARN the PID controller is not able to perform pressure control. Refer to
«LEARN (setup step 5)» for correct learn gas flow and procedure.
Set
16
51
Get
14
Y:
learn pressure limit according to selected DATA TYPE,
nominal pressure range is 0 ... 10'000 (sensor full scale) but it may be scaled,
refer also to command GAIN for details.
This command transfers/reads the pressure limit for LEARN.
Note: Refer to «LEARN (setup step 5)» for correct learn pressure limit setting.
Instance ID
Attribute ID
Description
1
105
1
107
1
108
1
0
1
100
Service
Service
data length
data field
(number of bytes)
X
1
X
1
X
1
-
-
Y
2 int
4 float
603476EA
71/102
2013-07-25