Table of Contents

Advertisement

Butterfly Pressure Control Valve
with DeviceNet interface
This manual is valid for the valve ordering number(s):
612 . . - . . GP - . . . .
612 . . - . . GQ - . . . .
612 . . - . . AP - . . . .
612 . . - . . AQ - . . . .
612 . . - . . HP - . . . .
612 . . - . . HQ - . . . .
612 . . - . . CP - . . . .
612 . . - . . CQ - . . . .
SPS = Sensor Power Supply
configured with firmware
The fabrication number is indicated on each product as per the label
below (or similar):
made in Switzerland
Fabrication No.:
patented
612 . . – . . . . – . . . . / . . . .
A – . . . . . .
Explanation of symbols:
Read declaration carefully before you start any other
action!
Attention!
Product is in conformity with EC guidelines,
if applicable!
Disconnect electrical power and compressed air
lines. Do not touch parts under voltage!
Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General
Safety Instructions» carefully before you start any other action!
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 612 DN 25-250 (I.D. 1" - 10"), DeviceNet
(1 sensor input)
(2 sensor inputs)
(1 sensor input / ±15V SPS)
(2 sensor inputs / ±15V SPS)
(1 sensor input / PFO)
(2 sensor inputs / PFO)
(1 sensor input / ±15V SPS / PFO)
(2 sensor inputs / ±15V SPS / PFO)
PFO = Power Failure Option
612P.1E.00 and 264420 (DeviceNet
. .
Fabrication number
®
)
Keep body parts and objects away from the valve
opening!
Hot surfaces; do not touch!
Loaded springs and/or air cushions are potential
hazards!
Wear gloves!
sample picture
265043EC
1/72
2009-12-17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 612 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VAT 612 Series

  • Page 1 Do not touch parts under voltage! Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General Safety Instructions» carefully before you start any other action! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 1/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 2 VAT products. The VAT firmware contains a limited, time unlimited user license. The VAT firmware may not be used for purposes other than those intended nor is it permitted to make copies of the VAT firmware. In particular, it is strictly forbidden to give copies of the VAT firmware to other people.
  • Page 3: Table Of Contents

    Durability of power fail battery ......................62 5.2.2 Retrofit / replacement procedure ....................... 63 6 Drawing................................... 66 7 Spare parts ................................67 VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 3/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 4 ISO-KF and ISO-F valve unit - aluminum blank, without heating..............68 Accessories ..............................70 7.4.1 Centering ring with Viton o-ring ......................71 8 Warranty ................................. 72 VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 4/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 5: Use Of Product

    This product is a Butterfly control valve for downstream pressure control in vacuum systems. Use product for clean and dry indoor vacuum applications under the conditions indicated in chapter «Technical data» only! Other applications are only allowed with the written permission of VAT. Technical data...
  • Page 6 Refer to chapter «Sensor supply concepts» for details. Refer to chapter «Schematics» for details. PFO = Power Failure Option. Refer to «Behavior in case of power failure» for details. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 6/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 7: Valve Unit

    Seal materials are declared on dimensional drawing of specific valve ordering number. ® - Slide bearing for shaft iglidur VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 7/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 8 7800 l/s 15000 l/s Dimensions Refer to dimensional drawing of specific valve ordering number (available on request) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 8/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 9: Installation

    Do not connect or disconnect sensor cable when device is under power. Connection overview Connectors at controller panel DeviceNet connector VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 9/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 10 Note: To provide power to the valve motor pins 4 and 8 must be bridged, otherwise motor interlock is active and the valve enters the safety mode and is not operative. Refer also to «Safety mode». This valve may optionally be equipped with a heating device. Connect VAT heating device according to manual of respective heating device.
  • Page 11: Tightening Torque

    13-15 9-11 13-15 9-11 13-15 9-11 Refer to «Spare parts and accessories» for centering rings ordering numbers. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 11/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 12: Mounting With O-Ring In Grooves

    Bending moment «M» size compressive force «F » mm inch lbf. 1½ 2½ 26.5 1000 1200 1200 1200 VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 12/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 13: Admissible Forces At Controller

    F = Force a = middle of aluminium part of controller (b / 2) pedestal 400 N pedestal VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 13/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 14: Requirements To Sensor Connection

    612 . . - . . A . - ../ 612 . . - . . C . - ..SPS module included Note: The SPS module can be retrofitted. Refer to chapter «Retrofit / replacement procedure» for instruction. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 14/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 15: Power And Sensor Connection (+24 Vdc Sensors)

    Do not connect other pins, that may damage power supply or controller! • Connector: Use only screws with 4-40UNC thread for fastening the connectors! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 15/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 16 • Connector: Use only screws with 4-40UNC thread for fastening the connectors! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 16/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 17: Power And Sensor Connection (±15 Vdc Sensors) Without Optional Sps Module

    Do not connect other pins, that may damage power supply or controller! • Connector: Use only screws with 4-40UNC thread for fastening the connectors! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 17/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 18 • Connector: Use only screws with 4-40UNC thread for fastening the connectors! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 18/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 19: Power And Sensor Connection (±15 Vdc Sensors) With Optional Sps Module

    Do not connect other pins, that may damage power supply or controller! • Connector: Use only screws with 4-40UNC thread for fastening the connectors! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 19/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 20: Devicenet® Connection

    The service port (connector: SERVICE) allows to connect the valve to a RS232 port of a computer. This requires a service cable and software from VAT. You can either use our freeware 'Control View', which can be downloaded from www.vatvalve.com or purchase our 'Control Performance Analyzer'.
  • Page 21: Operation

    Local operation means that the valve is operated via the service port using a computer or the Service Box 2. When using a computer, a service cable and a software from VAT are required. You can either download our freeware 'Control View' from or purchase our 'Control Performance Analyzer'.
  • Page 22: Remote Operation

    Refer also to chapter «Display information». Valve position after power up is closed Valve position after power up is open VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 22/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 23: Behavior In Case Of Power Failure

    Default is not defined. Display indicates F. *) Provided that battery pack of the VAT controller is charged. Charging time after power up is 2 minutes max.. All parameters are stored in a power fail save memory. VAT Vakuumventile AG, CH-9469 Haag, Switzerland...
  • Page 24: Display Information

    «Safety mode» for details. 1) SPS = optional ±15 VDC Sensor Power Supply module 2) PFO = Power Failure Option VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 24/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 25: Setup Procedure

    Refer to chapter «LEARN» for details. LEARN Note: Without LEARN the valve is not able to run pressure control VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 25/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 26: Devicenet Configuration

    ® VAT offers valve-related but not general DeviceNet support. Contact us under: devicenet-support@vat.ch The node number is the device address and can be selected by two rotary switches which are on the panel. Set the most significant digit (MSD) with the middle switch and the least significant digit (LSD) with the left switch.
  • Page 27: Valve And Sensor Configuration

    ‘Setup / Sensor’. Select SENSOR MODE Do 2 sensor configuration in menu ‘Setup / Sensor’. Select SENSOR RATIO VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 27/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 28: Zero

    Note: Do not perform ZERO, if the base pressure of your vacuum system is higher than 1‰ of sensor full scale. We recommend disabling ZERO function in this case; refer to «Valve and sensor configuration» of the setup procedure. Otherwise incorrect pressure reading is the result. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 28/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 29: Learn

    Note: Learn may take several minutes. Do not interrupt the routine as a single full run is required to ensure fast and accurate pressure control. The PID controller covers 5% to 5000% of the gas flow which was used for learn. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 29/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 30 [sccm] = 39.4 • p • C max. pressure to control [Torr] required lower conductance [l/s] VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 30/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 31: Close Valve

    = position control Select or enter position setpoint Send CONTROL MODE for position = control mode Send POSITION SETPOINT VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 31/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 32: Pressure Control

    SENSOR 1 READING and SENSOR 2 READING». Note: Make sure that both sensors are calibrated. Note: Do not close optional gauge isolation valves during the transition phase between the sensors. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 32/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 33: Tuning Of Control Performance

    Pumping speed (l/s) and pump type (e.g. turbo pump) • System description • Problem description Send diagnostic file with and all required information to tuning-support@vat.ch VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 33/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 34 Go to ‘Setup / Controller’ menu. Select PID CONTROLLER SENSOR DELAY Select sensor delay. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 34/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 35 Go to ‘Setup / Control Parameter’ menu. Select PID CONTROLLER SETPOINT RAMP Select setpoint ramp. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 35/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 36 ‘Service Box 2‘) commands» for details) Go to ‘Setup / Control Parameter’ menu. Select valve Select VALVE SPEED speed. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 36/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 37: Interface

    4)0 = Valve is neither closed nor open, 1 = Valve is CLOSED, 2 = Valve is OPEN 5)To activate ZERO or LEARN use 1 as data else 0. Apply always correct procedures as described in «ZERO (setup step 4)» or «LEARN (setup step 5)» VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 37/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 38: Assembly Object Bit Map

    SETPOINT TYPE may be set to one out of below selections, see also «Explicit messaging control commands». Description Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Pressure control Position control VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 38/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 39 Bit4 Bit3 Bit2 Bit1 Bit0 Valve is neither closed nor open Valve is closed Valve is open VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 39/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 40: Explicit Messaging Control Commands

    TYPE separately. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 40/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 41 This command writes/reads the respective assembly object. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 41/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 42: Explicit Messaging Inquiry Commands

    Value range is -1400 … +1400 (-1.40V … +1.40V). Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‘h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 42/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 43 Above picture shows a 2 sensor system. In this configuration sensor 2 covers low range (100 mTorr) and sensor 1 covers high range (1 Torr). Switchover between sensors is done automatically according to «Pressure control operation with 2 sensors». VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 43/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 44 Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‘h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 44/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 45 For meaning see table on next page. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 45/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 46 1) Refer to «Trouble shooting» for details on these fatal errors. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 46/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 47 Each closing of the sealing ring counts as one cycle. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 47/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 48: Explicit Messaging Setup Commands

    Not implemented Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 48/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 49 612 . . - . . H . - ..or 612 . . - . . U . - ..or 612 . . - . . W . - ..]. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‚h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 49/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 50 Note: Refer to «ZERO (setup step 4)» for correct zero procedure. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‘h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 50/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 51 ASCII coded. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‘h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 51/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 52 Note: Refer to «Valve speed adjustment» for details. Note: Unless otherwise specified all values in the table above are in decimal notification. Hexadecimal values are indicated by the letter ‘h‘ (e.g. 31h) VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 52/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 53: Trouble Shooting

    Read back from contoller is - Check poll rate - Refer to «Setup procedure, DeviceNet® configuration» for details. wrong during polling VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 53/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 54 - Select POSITION CONTROL mode. selected, check for V on Refer to «Position control» for details. display? VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 54/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 55 - Make sure a shielded sensor cable is used. If you need any further information, please contact one of our service centers. You can find the addresses on our website: http://www.vat.ch VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 55/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 56: Maintenance & Repairs

    Contamination from the process may influence the function and requires more frequent maintenance. Before carrying out any maintenance or repairs, please contact VAT. It has to be individually decided whether the maintenance/repair can be performed by the customer or has to be carried out by VAT. The fabrication number on the valve made in Switzerland Fabrication No.:...
  • Page 57: Maintenance Procedures

    A critical factor influencing the maintenance period is the lifetime of the vacuum grease, being limited under increased temperature. In this case grease will separate to PTFE and oil. The oil may flow and contaminate the valve parts. VAT can give the following recommendations for preventive maintenance: heated ≤ 80°C *) unheated *) heated >...
  • Page 58 For ordering number refer to «Spare parts and accessories». 12 mm 5. Unfasten screws and remove plate Allen Wrench from shaft. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 58/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 59 (0.025 ml). 11. Lubricate each o-ring with a slight film of vacuum grease (0.0125 ml). VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 59/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 60 (steps 6 to 17. Align pedestal parallel to valve body and tighten the 2 mounting screws with 2 Nm. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 60/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 61 Allen Wrench 21. Tighten clamp coupling with 1.1 Nm. 22. Reinstall valve into vacuum system according to chapter «Installation». VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 61/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 62: Option Board

    Ambient temperature [°C] Note: This graph shows estimated life of UltraCap PFO for reference and not as guaranteed value. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 62/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 63: Retrofit / Replacement Procedure

    Note: All boards have a fixed position into control and actuating unit. It is not possible to fit a board in other position as shown in picture above. Do not try out other positions, that may be destroy the socket of boards! VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 63/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 64 Disconnect fan cable from board. Push the connector release (1) a little down and disconnect DeviceNet cable (2) from interface board. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 64/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 65 «NODE ADDRESS» and «DATA RATE» on new Interface board that you wrote down on step 1. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 65/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 66: Drawing

    Installation, Operating & Maintenance Instructions Series 612 DN 25-250 (I.D. 1“ - 10”), DeviceNet Drawing VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 66/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 67: Spare Parts

    Option board with PFO module 378002 (power failure option) Option board 376837 with SPS and PFO module *) Too many to list. Depends on configuration, please contact VAT. Seals and grease Item Description Valve size All sizes Product ordering number 612 .
  • Page 68: Iso-Kf And Iso-F Valve Unit - Aluminum Blank, Without Heating

    • valves with JIS, ASA or CF-F flanges spare part ordering numbers are available on request. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 68/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 69 • valves with JIS, ASA or CF-F flanges spare part ordering numbers are available on request. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 69/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com...
  • Page 70: Accessories

    Special Allen wrench (SW3) 257820 • Allen wrench (SW2) • Feeler gauges: 0.04, 0.06 and 0.08mm each 6 pcs. VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 70/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 71: Centering Ring With Viton O-Ring

    32046-QAZV 32048-QAZV Centering ring with Viton o-ring (for ISO-F installation only) Stainless steel 32040-QEZV 32044-QEZV 32046-QEZV 32048-QEZV VAT Vakuumventile AG, CH-9469 Haag, Switzerland 265043EC 71/72 Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com 2009-12-17...
  • Page 72: Warranty

    (including any delay in or failure to deliver), packaging, storage or use of any product sold or delivered by VAT shall fail to conform to the...

Table of Contents