VAT 615 Series Installation, Operating, & Maintenance Instructions page 88

Dn 40 (i.d. 1 1/2”), devicenet, butterfly control & isolation valve with extended control range, with devicenet interface
Table of Contents

Advertisement

24. Clean shaft feed through
25. Clean the valve body
26. Lubricate seal contact surface of valve
body with a slight film of 0.0125 ml
vacuum grease
27. Lubricate seal contact surface of shaft with
a slight film of 0.0125 ml vacuum grease
28. Lubricate each o-ring with a slight film of
0.0125 ml vacuum grease.
Pay attention: If required use new o-rings
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½"), DeviceNet
Description
Required tool
Cleanroom wipes soaked
with isopropyl alcohol
Cleanroom wipes soaked
with isopropyl alcohol
Vacuum grease
Vacuum grease
Vacuum grease
603476EA
88/102
2013-07-25