VAT 615 Series Installation, Operating, & Maintenance Instructions page 72

Dn 40 (i.d. 1 1/2”), devicenet, butterfly control & isolation valve with extended control range, with devicenet interface
Table of Contents

Advertisement

Command
LEARN STATUS
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
Installation, Operating & Maintenance Instructions
Series 615 DN 40 (I.D. 1½"), DeviceNet
Service Code
Class ID
Get
14
51
This command returns the status of the LEARN procedure. The status is binary coded.
Bit
Explanation:
(LSB) 0
0 = LEARN not running
1 = LEARN running
1
0 = LEARN data set present
1 = LEARN data set not present
2
0 = ok
1 = LEARN terminated by user
3
0 = ok
1 = pressure in position OPEN
> 50% sensor full scale
or
> LEARN PRESSURE LIMIT
4
0 = ok
1 = pressure in position 0
< 10% sensor full scale
5
0 = ok
1 = pressure falling during LEARN
6
0 = ok
1 = sensor not stable during LEARN
7
reserved
8
reserved
9
reserved
10
0 = ok
1 = LEARN terminated by controller
11
0 = ok
1 = pressure in position OPEN negativ
12
reserved
13
reserved
14
reserved
15
reserved
(MSB) 16
reserved
Instance ID
Attribute ID
Description
1
106
(of high range sensor in case of a 2 sensor system)
(of low range sensor in case of a 2 sensor system)
Service
Service
data length
data field
(number of bytes)
2
603476EA
72/102
2013-07-25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

61532-keaq-0001