Procedure

NOTE
Disposal
Dispose of the contents of the container in accordance with local,
national, and international regulations.
To change the water, proceed as follows:
ü The unit is switched on.
ü No machining process is running.
ü Open the drawer.
1. Pull the water tank out.
2. Open the drain opening (D).
3. Empty two thirds of the water from the tank.
4. Close the drain opening (D).
5. Shake the tank vigorously.
6. Open the drain opening (D).
7. Drain the rest of the water.
8. Close the drain opening (D).
9. Turn the tank cap (B) counter-clockwise and take it off.
NOTE
Foaming not permissible!
If any cleaning agents are used, this will create foam, which is not
permitted.
Do not use any cleaning agents.
10. Add 75 ml of DENTATEC to the tank.
11. Fill the tank with water until the filter insert (C) is completely
immersed (up to the bottom edge of the cover thread, approx.
3.5 liters).
12. Wait for a short time until the filter insert (C) is completely soaked;
then add an appropriate amount of water.
13. Close the water tank by tightening the tank cap (B) clockwise by
hand. Do not use the tank cap opener for this.
14. Push the water tank back into the housing.
15. Select the symbol shown on the left in the touch display.
16. To reset the water tank counter, press the "Check" button next to
the "Water Tank" category.