This function provides unsetting of the system in a special mode. The system seemingly unsets, however
it triggers a silent panic alarm, which is then reported to selected users (including ARC).
Unsetting under duress is executed by adding 1 to the last number in a valid code.
Example for a code with the prefix:
Valid code: 2*9999
Example for a code without the prefix:
Valid code: 9999

2.1.2.4 PARTIAL ALARM SETTING

1. Authorize yourself using
the keypad (enter a code or hold
a card or a tag up to the reader).
The green backlit indication button
will start flashing.
The system can also be configured to be partially set which allows guarding only by certain detectors
in a section.
Example: At night, it is possible to set the door and window detectors only, while motion detectors inside
a house do not react to anything.
To fully set the premises in which partial setting is enabled, the button to set the system has to be pressed
twice. After the button is pressed once it flashes yellow, when it is pressed a second time it flashes red.
If the system is partially set – indicated by a continuous yellow light – the entire system can be fully set
by authorization and pressing the yellow button. Once the button is pressed, the system will be fully set and
the button turns red.

2.1.2.5 TERMINATING A TRIGGERED ALARM

1. Authorize yourself
using the keypad (enter
a code, hold a tag
up to the reader).
Code for unsetting under duress: 2*9990
Code for unsetting under duress: 9990
2. Press the right segment button
of the selected section.
2. Press the left
segment button
of the section where
the alarm has been
triggered.
3. The command is executed,
and the segment button turns
yellow to indicate a partially set
section.
3. Unsetting is finished
and sirens are silenced.
The green flashing
button indicates
unsetting of the parti-
cular section. The red
flashing light indicates
alarm memory.
4. Authorize yourself
and press the green
button again to cancel
the alarm memory
indication.
5. The segment indica-
tes the unset section
with a continuously lit
up green button.