Detectors; Controllers; Output Devices; Telephone Dialer Module Ja60X - jablotron JA60K Installation Manual

Table of Contents

Advertisement

The following description includes only the basic assortment of accessories. In annex A of this manual you will find a copy
of the particular item manuals for your information. We systematically introducing new and improved JA-60 items to the
market. You can get the most current information from your distributor.

8.1.1. Detectors

JA60M Magnetic door detector - is equipped with a magnet. Movement of the magnet triggers the internal sensor in the
detector. It can trigger an Instant or Delayed intruder alarm and it also has built in tamper detectors. There are inputs for
external sensors (see section 8.2.1. for more details).
JA60P Motion detector– triggers an Instant or Delayed intruder alarm when the movement of a human body is detected.
It has built in tampering sensors and it uses digital processing of the signal for a high false alarm immunity.
JA60S Smoke detector– triggers a Fire alarm when smoke is detected. It also has a built in siren.
JA60G Gas leak detector– triggers a Fire alarm when any combustible gas is detected (natural gas, city gas, propane,
butane etc.). The detector is powered directly form the AC power network and it wirelessly transmits information to the
control panel. The JA60G has a built in siren and an output relay. The relay, for example, can be wired to an electrical
valve to turn off the gas supply when a leak is detected.

8.1.2. Controllers

RC11 Remote control– can be used to Arm and Disarm the system. It can also be used to trigger a silent Panic alarm.
RC22 Panic button - is a large size button, which can be easily attached in a selected location (under a desk, on the wall
etc.). This button can be used to trigger a silent Panic alarm. The RC22 can be enrolled to the control panel the same way
as the remote control.
JA60D Wireless keypad– can operate the system in a similar way as the built in keypad on the control panel (arming,
disarming, no code arming, partial arming, door opening and under duress operation). It has its own Master code and one
User code, which can be programmed independently from the control panel's codes.

8.1.3. Output devices

Wireless siren JA60A is designated for outdoor use. It is powered from its own AC adapter and it has a built in back up
battery. The siren wirelessly communicates with the control panel. It contains a high powered siren and a flashing light.
Besides signaling alarms, it can also provide arming and disarming chirps. The siren has built in tamper detectors. Only
one JA60A siren can be used with each JA-60 control panel.
Wireless outputs unit UC216 is a receiver, which receives signals from the JA-60 control panel. The unit has two output
relays (X and Y, max. load 120V / 1A each). These relays have identical functions as outputs PgX and PgY of the control
panel (see 7.2.5). The unit requires external power from 12 to 24VDC or 15VAC. Multiple UC216's can be used with a
control panel and each UC216 can receive signals from more than one control panel.
Wireless output unit UC222 is a receiver, which receives signals from the JA-60 control panel. The unit has a power
output relay (max. 250VAC / 5A). This relay has an identical function as output PgX of the control panel (see 7.2.5). The
unit is powered directly from the AC power (220 or 110VAC options). Multiple UC-222's can be used with a control panel
and each UC-222 can receive signals from more than one control panel.
Use of UC216 and UC222 directly with JA-60 detectors – the wireless output modules can also be used directly with
JA-60 system items (detectors, keypads, remote controls). In this case the receiving unit reacts to the signals from the
items which were enrolled to this unit. The item can be a part of the JA-60 alarm system and its data is received by both
the control panel and the UC receiver. Or, the items can be used with UC units directly..

8.1.4. Telephone dialer module JA60X

– the control panel is available without the dialer (model JA-60K) or with
the built in dialer (model JA-60KX). The JA60X dialer module can be easily installed to a JA60K control panel as an after
market accessory. The dialer can send a voice message to four telephone numbers and it can also send a numeric mes-
sage to a Pager. The dialer regularly checks if the telephone line is ready, yet allows the line to be used as a normal phone
line inside the house. The dialer can also communicate with a monitoring station or with a remote PC. Information about
the monitoring station communication is provided only to the monitoring station providers.

8.1.5. PC interface cable PC60A

– can be used to connect the control panel to a serial port (COM1 or COM2) in
your computer. Suitable SW, ComLink, is provided on a floppy disk. The software is a convenient way to setup the control
panel, to supervise the system which is on line, to read, view and store data from the event memory and to record other
information about the system. The software can be installed under MS DOS or Windows system. You can learn more
about the SW features, when you install it on your computer. Even without the PC60A interface cable you will be able to
run the software in its off-line mode. The software has a built in help section.
If the control panel is equipped with the JA-60X dialer, then it is also possible to dial in the system from a remote PC us-
ing the ComLink SW. For remote access the PC must be equipped with modem model JA60U.

8.1.6. Control panel as a subsystem

Alarm system JA-60 "COMFORT"
-
18 -
MDY51306

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ja60x

Table of Contents